,

ANTSPACE HK3 (with DWT-T) Container


$75.000$80.000

Compare

Built with efficiency and hotter climates in mind, the BITMAIN ANTSPACE HK3 (known as model designation Antbox H3 V2 internally) has a maximum capacity of 210 units Rack Space.

Bitmain’s First Liquid Cooling Antbox

Diagram of Liquid Cooling Antbox water circuit

Specifications

Input voltage, V 415±5% AC/60Hz/3P/N/PE
Total power consumption, kW (load shared by two power distribution
cabinets)
1047
Miner power consumption W 4900-5400
Miner inlet/outlet water temperature, ℃ 35/45
Container size (length * width * height) 6058*2438*2896
Cooling tower size (length*width*height) 5800*2240*4286
Weight, T (empty weight of cooling tower/operating weight) 6/10
Weight, T (container without miner/with miner weight) 8/12
Cooling tower spray flow, m³/h 233
Heat dissipation capability kW 1000
Inlet and outlet temperature rise ΔT,° 10
Cooling tower docking interface specifications DN125
Heating docking interface specifications DN100
Cooling tower water inlet specifications DN40
Cooling tower drain specifications DN65
Heating piping pressure bearing capability kg 10
Design flow on heating side, m³/h 85
Temperature variation between inlet and outlet(heating side)ΔT 10

Environmental Requirementss

1 Cooling tower is required to be placed on flat ground, horizontal degree (±1 degree).
2 The ground surfaced is required to be hardened and stable, able to withstand at least 14-ton load.
3 A 10-ton crane is needed for unloading ANTSPACE and cooling tower.
4 Add-on items such as stairs, transformers, cables, bridge racks and cable distribution boxes are not included in the delivery of ANTSPACE. We team can provide design suggestions if needed.
5 Client needs to confirm the opening directon of container and it needs to face air-intake. Door on left is current design by defult.
6 Keep at least 2 meters of air in-take space around the cooling tower.
7 Altitude: ≤3000m. If the altitude is higher than 1000-meter, transformer and switch should be derated, the total power of ANTSPACE must be decreased by 1% for each elevation increment of 100 meters.
8 Operating temperature: -25°C to 40°C. Operating humidity: 10%RH to 90%RH. When the initial coolant temperature is below 20 °C, the internal circulation should be turned on to heat up the coolant to above 20 °C before starting the mining machine.
9 When the ambient temperature is below 5 ℃, the cooling tower can be switched to cold-dry mode.
10 Choose pure water or suitable antifreeze as coolant based on local climate conditions.
11 The suitable ambient temperature for ANTSPACE does not represent the suitable ambient temperature for mining machine.
SKU: N/A Categories: , Tags: ,
× How can I help you?